Thermal Imaging & Thermography Specialists

Thermal Imaging.
Scanned. Scored. Fixed.

A loose connection gets hot long before it trips, sparks or starts a fire. We scan boards, switchgear and connections live, under normal load, with a calibrated infrared camera — so a developing fault shows up as a heat signature on a report, not as downtime or a callout.

NICEIC REGISTERED LIVE, UNDER-LOAD SURVEYS CALIBRATED INFRARED CAMERAS INSURER-READY REPORTS

Registered, approved and independently certified

Why it matters

The standards we work to

Thermography sits alongside — not instead of — a periodic inspection. Every survey is carried out and reported against the specific standard your installation and insurer expect.

IET/ITC Code of Practice for Thermographic Inspection

Survey methodology

Sets out camera calibration, load conditions and reporting format for electrical thermographic surveys.

ISO 18434-1

Condition monitoring

The international standard for infrared thermography as a condition-monitoring technique on electrical and mechanical plant.

Electricity at Work Regs 1989

Ongoing maintenance duty

Requires fixed electrical systems to be maintained to prevent danger — thermography is recognised evidence of that maintenance.

RRFSO 2005

Fire risk overlap

Loose connections and overheating components are a leading cause of electrical fire — findings feed directly into your fire risk assessment.

Insurance & Underwriter Requirements

Cover validity

Many commercial and industrial policies require an annual thermal imaging survey of switchgear and distribution equipment to keep cover valid.

BS 7671

Wiring regulations

Where a survey identifies a fault, remedial work is carried out and certified against BS 7671 in the usual way.

Severity scale

Every hot spot gets a severity rating, every rating gets a timescale

We classify every anomaly by temperature rise above ambient/reference, so you know exactly how urgent each finding is before we leave site.

T1 — Emergency

>40°C rise — immediate danger, isolated or made safe on site where possible

T2 — Serious

15-40°C rise — repair required within days, not the next scheduled visit

T3 — Moderate

4-15°C rise — schedule repair, monitor at next survey if left

T4 — Advisory

<4°C rise — noted for the record, re-check at the next scheduled survey

SATISFACTORY

No thermal anomalies detected — passes for the survey interval

UNSATISFACTORY

One or more T1 or T2 findings present — remedial action required

Where we work

Every sector runs a different survey interval

The right interval depends on load, duty cycle and consequence of failure — we scope to the sector and your risk profile, not a generic minimum.

5 YEARS

Domestic / Private Rented

Board thermal check bundled with the periodic inspection cycle

ANNUAL

Commercial / Office

Main distribution boards and floor boards scanned yearly, often insurer-driven

ANNUAL / 6-MONTHLY

Industrial / Warehouse

Motor control centres and switchgear on a shorter cycle given fire load

ANNUAL

Residential Blocks

Communal riser and plant room switchgear surveyed annually

CONTINUOUS

Data Centres & Server Rooms

Fixed sensor monitoring plus periodic full infrared survey

6-MONTHLY

Healthcare & Care Homes

Critical and life-safety boards surveyed on a shortened interval

ANNUAL

Hospitality & Hotels

Kitchen extract and plant boards scanned given continuous high load

ANNUAL

Education

Kitchen and workshop boards surveyed ahead of each academic year

6-MONTHLY

Retail / Cold Storage

Refrigeration and plant switchgear on a shorter cycle given continuous duty

ANNUAL

Fleet / EV Charging Hubs

High-power charging infrastructure scanned under peak load conditions

Service packages

Survey, monitoring or full remedial cover — your choice

A hot spot found early is a re-torque; found late, it's a burnt-out board. Pick the level of cover that matches how much of that gap you want us to close.

Level 1
Survey Only
£12/month per board

A recurring live thermal survey on a fixed interval, with every finding classified and reported.

  • Full infrared survey under normal load
  • Every anomaly severity-rated and reported
  • Thermal image evidence attached to every finding
  • Survey reminders before due date
Start Survey Only
Level 3
Full Lifecycle Plan
£36/month per board

Survey and remedial work with component or board replacement at end-of-life, built in and amortised.

  • Everything in Maintenance Plan
  • Breaker, connector or board replacement included at expiry
  • Optional fixed thermal sensor install for continuous monitoring
  • Compliance pack export for insurance/audit
Start Full Lifecycle
Multi-Site / Portfolio
Enterprise Plan
Customquoted per board count

Scoped to your total board and switchgear count across sites, with risk-based interval assignment.

  • Multi-site survey scheduling
  • Risk-based interval assignment per board
  • Portfolio thermal trend dashboard
  • Remedial works SLA
Request a scope
Previous work

Survey, remedial work and replacement across every sector

A representative sample of recent work. Full case studies and references available on request.

Office Block
Commercial · London

Annual switchboard survey

Full infrared survey across three floor distribution boards, one T2 loose termination found and re-torqued same visit.

ITC Code of PracticeSatisfactory — 1 T2 resolved
Distribution Warehouse
Industrial · Essex

Motor control centre survey

Survey across the main MCC and racking power distribution, one T1 emergency finding isolated and made safe on the day.

ISO 18434-1Satisfactory — T1 made safe
Cold Storage Facility
Retail / Cold Storage · Kent

6-monthly refrigeration switchgear survey

Refrigeration plant switchgear surveyed under peak compressor load, two T3 findings scheduled for next visit.

ITC Code of PracticeSatisfactory, 2 T3 noted
Care Home
Healthcare · Surrey

Critical board survey — 40-bed facility

Life-safety and critical power boards surveyed on a 6-monthly cycle, no anomalies detected.

ITC Code of PracticeSatisfactory — 0 anomalies
Data Centre
Data Centre · London

Continuous monitoring & annual survey

Fixed thermal sensors installed on critical UPS and distribution boards, backed by a full annual infrared survey.

ISO 18434-1Satisfactory — sensors live
Boutique Hotel
Hospitality · London

Kitchen extract board survey

Commercial kitchen extract and plant boards scanned under continuous load, one connector replaced after a T2 finding.

ITC Code of PracticeSatisfactory — 1 T2 resolved
Mixed-Use Block
Residential Block · London

Communal switchgear survey

Riser and plant room switchgear surveyed annually across a managed block, no anomalies detected.

ITC Code of PracticeSatisfactory — 0 anomalies
Delivery Depot
Fleet / EV Charging · Essex

Charging hub survey under peak load

20-bay fleet charging hub scanned under peak simultaneous-charging load, no anomalies detected.

ITC Code of PracticeSatisfactory — 0 anomalies

Representative examples — site names withheld for client confidentiality. Ask for references relevant to your sector.

Coverage

Areas we serve

Accredited thermography engineers across Leysdown-on-Sea and Kent, with every survey logged to your compliance record wherever your sites are.

Leysdown-on-Sea — & surrounding areas in Kent

Every borough, one service team

CamdenIslingtonHackneyWestminsterKensingtonChelseaHammersmithFulhamWandsworthLambethSouthwarkTower HamletsNewhamBarnetEnfieldHaringeyWaltham ForestRedbridgeHounslowEalingBrentHarrowHillingdonCroydonBromleyLewishamMertonSutton

Hertfordshire

WatfordSt AlbansStevenageWelwyn Garden CityHatfieldHertfordCheshuntPotters BarHarpenden

Essex

ChelmsfordColchesterBasildonSouthendBrentwoodHarlowEppingLoughton

Kent

MaidstoneCanterburyDartfordMedwayTunbridge WellsSevenoaks

Surrey

GuildfordWokingEpsomReigateCamberley

Berkshire

ReadingSloughWindsorMaidenheadBracknell

Buckinghamshire

Milton KeynesAylesburyHigh Wycombe

Bedfordshire

LutonBedfordDunstable

Norfolk

NorwichKing's LynnGreat Yarmouth

Suffolk

IpswichBury St EdmundsLowestoft

Cambridgeshire

CambridgePeterboroughEly
Ad-hoc pricing

Prefer to pay per visit? Fixed prices for that too

Care packages above are cheaper over time — but every service is also available as a one-off, fixed price upfront.

ServiceStandardFrom
Survey
Domestic consumer unit thermal surveyITC Code of Practice£75
Commercial distribution board survey (per board)ITC Code of Practice£120
Motor control centre / switchgear survey (per panel)ISO 18434-1£175
Additional board on same visit (per board)ITC Code of Practice£50
Monitoring & Maintenance
Fixed thermal sensor installation (per board)ISO 18434-1£380
Loose connection re-torque (per item, T3/T2)BS 7671£55
T1 emergency isolation & made safe (per item)BS 7671£65
Re-survey & satisfactory report issueITC Code of Practice£95
Replacement
Breaker / RCBO replacement following finding (per item)BS 7671£75
Busbar or connector replacement (per item)BS 7671£220
Board replacement following repeat/critical findingsBS 7671£750
Switchgear / MCC replacement (per panel)BS 7671Custom quote
Book or enquire

Book a visit, or send us your enquiry

Domestic and single-board jobs — book a live slot instantly. Multi-board, commercial and portfolio work — send an enquiry and we'll come back with a fixed quote.

Book a live slot

Real-time availability via our booking system. Opens in a new tab.

If the calendar above doesn't load, open live booking in a new tab →

Book this service

Sent securely to our team — no email app required.

We reply within one working day. For anything urgent, call 0203 908 4790.

Questions

Frequently asked

What is a thermal imaging survey?

An infrared camera scans boards, switchgear and connections while the installation is live and under normal load, producing a heat map that reveals loose connections, overloading and failing components before they trip, spark or fail.

How often should a thermal survey be carried out?

It depends on load and consequence of failure: annually is typical for commercial and industrial switchgear, 6-monthly for critical or continuous-duty plant such as healthcare, cold storage and data centres, and domestic boards are usually checked as part of the periodic inspection cycle.

Is thermal imaging a substitute for an EICR?

No — thermography is a live, non-invasive check for heat-related faults under load. It complements a full periodic inspection (EICR) rather than replacing it, and is often used between EICR cycles to catch developing faults early.

What happens if a hot spot is found?

Every finding is classified by severity (T1 to T4). T1 emergency findings are isolated or made safe immediately where possible; T2 findings are scheduled for repair within days; T3 and T4 findings are noted and monitored or scheduled for the next convenient visit.